Esco Ductless Fume Hoods
Esco Ascent Ductless Fume Hoods provide protection to both laboratory personnel and the environment from toxic fumes and are quickly becoming a viable alternative to conventional fume hoods. Unlike conventional fume hoods, these hoods filter out chemical fumes and recycle air directly back to the laboratory, providing energy savings, personnel and environmental protection, convenience as you do not have to deal with complicated ducting systems, and mobility, since ductless hoods are independent systems which do not require connection to extraction systems.
Ascent® Max Ductless Fume Hood - Standard Model ADC (B-Series)
The Standard Ascent Max Ductless Fume Cabinet offers a sensible balance of quality, performance features and cost-effectiveness.
Key Benefits:
- Certified to AFNOR NF X 15-203, BS7258, BS7989, ASHRAE110, EN14175-3
- 5 years limited warranty
- Large working area
- Generous carbon filter weight
- Robust steel carcass construction
- Isocide powder coating
- Excellent aesthetics
- State of the art Sentinel airflow monitor and alarm system
Features:
- Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
- Lip at the front edge of the work surface ensures that any spillage is contained within the workzone.
- A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
- Built-in 5000k warm white fluorescent lighting.
- Front service panel opens up easily for immediate access for all maintenance functions.
- Small Filter ID window to easily identify the type of filter being used.
- Powder-coated, panel-mounted single electrical outlet provision.
- Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
- All cabinet service and filter replacement can be carried out from the front, allowing the cabinet to be placed against walls in the laboratory to save space.
- Electronic module behind the hinged front panel for easy access during troubleshooting and certification.
- Retrofit Kit™ service fixture for air/water/vacuum/gas outlets.
- Retrofit Kit™ Polypropylene drip-cup sink and epoxy powder-coated swan neck faucet.
- Exhaust collar for added operator safety.
- VOC sensor to monitor the chemical concentration within the cabinet workzone.
- Base cabinet and support stand accesories.
- Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
Ascent® Max Ductless Fume Hood - With Secondary Back Up Carbon Filter ADC (C-Series)
The Ascent Max Ductless Fume Hood with secondary back up carbon exhaust filter offers a higher filtration efficiency against toxic fumes.
Key Benefits:
- Certified to AFNOR NF X 15-203, BS7258, BS7989, ASHRAE110, EN14175-3
- 5 years limited warranty
- Large working area
- Robust steel carcass construction
- Isocide powder coating
- Excellent aesthetics
- Elegant and smooth sliding sash window
- State of the art Sentinel airflow monitor and alarm system
Features:
- Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
- Lip at the front edge of the work surface ensures that any spillage is contained within the workzone.
- A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
- Built-in 5000k warm white fluorescent lighting.
- Front service panel opens up easily for immediate access for all maintenance functions.
- Small Filter ID window to easily identify the type of filter being used.
- Powder-coated, panel-mounted single electrical outlet provision.
- Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
- All cabinet service and filter replacement can be carried out from the front, allowing the cabinet to be placed against walls in the laboratory to save space.
- Electronic module behind the hinged front panel for easy access during troubleshooting and certification.
- Retrofit Kit™ service fixture for air/water/vacuum/gas outlets.
- Retrofit Kit™ Polypropylene drip-cup sink and epoxy powder-coated swan neck faucet.
- Exhaust collar for added operator safety.
- VOC sensor to monitor the chemical concentration within the cabinet workzone.
- Secondary back-up activated carbon filter (complies with the requirements of ANSI/AIHA Z9.5-2003).
- Base cabinet and support stand accesories.
- Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
Ascent® Max Ductless Fume Hood - With Transparent Back Wall (D-Series)
The Ascent Max Ductless Fume Hood with transparent glass back wall gives maximum visibility, ideal for classrooms and educational demonstrations.
Key Benefits:
- Certified to AFNOR NF X 15-203, BS7258, BS7989, ASHRAE110, EN14175-3
- 5 years limited warranty
- Large working area
- Robust steel carcass construction
- Isocide powder coating
- Excellent aesthetics
- Elegant and smooth sliding sash window
- State of the art Sentinel airflow monitor and alarm system.
Features:
- Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
- Lip at the front edge of the work surface ensures that any spillage is contained within the workzone.
- A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
- Built-in 5000k warm white fluorescent lighting.
- Front service panel opens up easily for immediate access for all maintenance functions.
- Small Filter ID window to easily identify the type of filter being used.
- Powder-coated, panel-mounted single electrical outlet provision.
- Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
- All cabinet service and filter replacement can be carried out from the front, allowing the cabinet to be placed against walls in the laboratory to save space.
- Electronic module behind the hinged front panel for easy access during troubleshooting and certification.
- Retrofit Kit™ service fixture for air/water/vacuum/gas outlets.
- Retrofit Kit™ Polypropylene drip-cup sink and epoxy powder-coated swan neck faucet.
- Exhaust collar for added operator safety.
- VOC sensor to monitor the chemical concentration within the cabinet workzone.
- Base cabinet and support stand accesories.
- Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
Ascent® Max Ductless Fume Hood - With Secondary HEPA Filter (E-Series)
The Ascent Max Ductless Fume Hood with secondary back up HEPA filter with efficiency of 99.99% at 0.3 microns is available in addition to carbon filter, suitable for applications involving the next generation of biohazardous aerosols in the work zone.
Key Benefits:
- Certified to AFNOR NF X 15-203, BS7258, BS7989, ASHRAE110, EN14175-3
- 5 years limited warranty
- Large working area
- Robust steel carcass construction
- Isocide powder coating
- Excellent aesthetics
- Elegant and smooth sliding sash window
- State of the art Sentinel airflow monitor and alarm system.
Features:
- Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
- Lip at the front edge of the work surface ensures that any spillage is contained within the workzone.
- A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
- Built-in 5000k warm white fluorescent lighting.
- Front service panel opens up easily for immediate access for all maintenance function.
- Small Filter ID window to easily identify the type of filter being used.
- Powder-coated, panel-mounted single electrical outlet provision.
- Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
- All cabinet service and filter replacement can be carried out from the front, allowing the cabinet to be placed against walls in the laboratory to save space.
- Electronic module behind the hinged front panel for easy access during troubleshooting and certification.
- Retrofit Kit™ service fixture for air/water/vacuum/gas outlets.
- Retrofit Kit™ Polypropylene drip-cup sink and epoxy powder-coated swan neck faucet.
- Exhaust collar for added operator safety.
- VOC sensor to monitor the chemical concentration within the cabinet workzone.
- Secondary back-up HEPA filter (complies with the requirements of ANSI/AIHA Z9.5-2003).
- Base cabinet and support stand accessories.
- Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
Ascent® Opti Ductless Fume Hoods
Probably the most technologically advanced low-cost ductless fume cabinet in the world, the Esco Ascent Opti Ductless Fume Cabinet can be enjoyed at an economical cost and is equipped with features previously found only on high-end ductless fume cabinets.
Key Benefits:
- Certified to AFNOR NF X 15-203, BS7258, BS7989.
- 3 years limited warranty
- Low Cost
- Easy to install
- Oval shaped arm ports provide good working flexibility and high containment levels
- State of the art airflow monitor and alarm system.
Features:
- Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
- A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
- Built-in 5000k warm white fluorescent lighting.
- Removable work surface on a removable drain-pan for easy cleaning.
- Small Filter ID window to easily identify the type of filter being used.
- Optional transparent back , ideal for classroom demonstrations.
- Optional mobile cart for convenient relocation. Cart is equipped with shelves for storage purposes.
- Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
- Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
- Extremely low energy consumption.
- Low noise levels (55 dBA).
- 2 provisions for electrical wiring at the back to easily connect any apparatus to a power supply from inside the main chamber.